Abstract


Human safety against touch voltage hazards is the most important factor in electrical power systems. Touch voltage hazards can occur if a person directly or indirectly touches live electrical parts. Indirect contact can happen when a person touches exposed conductive parts of equipment that are normally not energized but can become energized due to leakage current caused by insulation failure in electrical cables. Therefore, protection against indirect touch voltage is necessary. This study aims to analyze the protection against indirect contact voltage using an Earth Leakage Circuit Breaker (ELCB) and a Miniature Circuit Breaker (MCB). In this study, a 30 mA ELCB and a 2 A MCB were used as protection against indirect touch voltage hazards. The research data were obtained using the experimental method by conducting laboratory experiments. The laboratory experiment results showed that the 30 mA ELCB is more sensitive as protection against indirect touch voltage compared to the MCB. This is because the working principle of the ELCB is based on the leakage current occurring at the exposed conductive parts, whereas the working principle of the MCB is based on the total current (leakage current and load current) flowing through the MCB.

Keywords


ELCB, MCB, Proteksi, Tegangan sentuh

Full Text:

References


SNI-0225:2011, Persyaratan Umum Instalasi Listrik 2011, Jakarta: BSN, 2011.

A. Fathudin, “Evaluasi Sistem Penangkal Petir di Gedung Instalasi Radiometalurgi,” Prosiding Seminar EBN, 2017, pp. 247-258.

Sunarto, “Perbaikan Resistansi Elektroda Pembumian Instalasi Listrik Pemanfaat untuk memperkecil Bahaya Sengatan Listrik,” Jurnal Poli Teknologi, vol. 19, no. 3, pp. 241-251, 2020.

D. E. Putra, “Pengukuran Grounding SDP Panel Distribusi Instalasi Rekam Medis RSUP Dr. Mohammad Hoesin Palembang,” Jurnal Ampere, vol. 3, no. 1, pp. 128-139, 2018.

D. Setiawan, “Analisis Pengaruh Penambahan Garam dan Arang Sebagai Soil Treatment dalam Menurunkan Resistansi Pentanahan Variasi Kedalaman Elektrode,” Jurnal Transient, vol. 7, no. 2, pp. 416-423, 2018.

Y. Martin, “Pengaruh Pencampuran Gypsum Sebagai Zat Aditif Untuk Penurunan Nilai Resistansi Grounding Pada Elektroda Batang Tunggal,” Seminar Nasional Teknik Elektro Batu Malang, 2018, pp. 98-102.

F. D. Sukardi, “Prototipe Pengaman Peralatan Instalasi Listrik dan Tegangan Sentuh Bagi Manusia dengan ELCB ( Earth Leakege Circuit Breaker )”, Jurnal Teknologi Elekterika, vol. 16, no. 2, pp. 56-62, 2019.

A. Budiman, “Analisa Tahanan Pembumian Peralatan Gedung Laboratorium Teknik Universitas Borneo Tarakan yang Menggunakan Eelektrode Pasak Tunggal Panjang 2 Meter,” Jurnal JPE, vol. 21, no. 1, pp. 75-80, 2017

A. Budiman, “Analisa Perbandingan Tahanan Pembumian Peralatan Elektrode Pasak pada Gedung Laboratorium Teknik Universitas Borneo Tarakan,” Jurnal Nasional Teknik Elektro, vol. 6, no. 3, pp. 152-158, 2017.

Sunarto, “Rekonfigurasi Elektroda Pembumian Petir di Laboratorium Instalasi Listrik Politeknik Negeri Bandung,” Prosiding Semnastera, 2020, pp. 16-20.

R. Diamanis, “Analisa Jarak Paralel Antara Konduktor Sistem Grounding Grid PLTP Lahendong Unit 5 Dan 6,” Jurnal Teknik Elektro dan Komputer, vol. 7, no. 3, pp. 239-250, 2018.

Sunarto, “Studi perbandingan hasil pengukuran resistansi pembumian menggunakan tiga metode pengukuran yang berbeda,” JITEL, vol. 1, no. 2, pp. 155-162, 2021.

Latifah, “Penentuan Tipe Miniature Circuit Breaker 4A Untuk Instalasi Rumah Tinggal Melalui Pengujian Kinerjanya, Elit Journal, vol. 2, no. 1, pp. 43-51, 2021




DOI: https://doi.org/10.30591/polektro.v13i3.7210

Refbacks

  • There are currently no refbacks.


Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

----------------------------------------------------------------------------------------------------------------------

Indexed By :

 

 

 

 

----------------------------------------------------------------------------------------------------------------------

Tim Redaksi POWER ELEKTRONIK : JURNAL ORANG ELEKTRO

Program Studi D3 Teknik Elektro
Politeknik Harapan Bersama Tegal
Jl. Mataram No.09 Pesurungan Lor Kota Tegal

Telp. (0283) 350567

Email :
powerelektronik.ejournal@poltektegal.ac.id

 

Free counters!

View Visitor Statistic

 

Power Elektronik : Journal Orang Elektro licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.